  "model": "VT-CE-CM2",
  "language": "en",
  "reviewed": "2026-09-09",
  "method": "Figures retain their units, source and conditions. Calculations are examples, not test results. Unknown water use, actual energy consumption and labor savings are not recorded as zero.",
  "unquantified": [
    "water consumption",
    "measured energy consumption",
    "labor savings"
  ],
  "facts": [
    {
      "id": "throughput",
      "@type": "PropertyValue",
      "propertyID": "VT-CE-CM2:throughput",
      "name": "Rated throughput",
      "minValue": 300,
      "maxValue": 400,
      "unitText": "molds/h",
      "description": "Reference value · Indicative throughput. Actual output depends on soil, mold size, cycle settings and loading time.",
      "url": "https://cakemoldwasher.com/blog/chiffon-cake-ring-stuck-residue-cleaning/#documented-numbers-throughput",
      "classification": "reference",
      "approximate": false,
      "source": {
        "url": "https://cakemoldwasher.com/media/vtai-ce-cm2-product-sheet-zh.pdf#page=2",
        "reviewed": "2026-09-08"
      }
    },
    {
      "id": "overallDiameter",
      "@type": "PropertyValue",
      "propertyID": "VT-CE-CM2:overallDiameter",
      "name": "mold diameter",
      "minValue": 6,
      "maxValue": 14,
      "unitText": "in",
      "unitCode": "INH",
      "description": "Documented specification · Confirm material, coating, height and profile with our team. Sample testing is recommended for delicate coatings and unusual shapes.",
      "classification": "documented",
      "approximate": false,
      "source": {
        "url": "https://cakemoldwasher.com/media/vtai-ce-cm2-product-sheet-zh.pdf#page=2",
        "reviewed": "2026-09-08"
      }
    },
    {
      "id": "power",
      "@type": "PropertyValue",
      "propertyID": "VT-CE-CM2:power",
      "name": "Total electrical load",
      "value": 0.5,
      "unitText": "kW",
      "unitCode": "KWT",
      "description": "Documented specification · Electrical power rating, not measured energy consumption.",
      "url": "https://cakemoldwasher.com/blog/chiffon-cake-ring-stuck-residue-cleaning/#mold-numbers-power",
      "classification": "documented",
      "approximate": false,
      "source": {
        "url": "https://cakemoldwasher.com/media/vtai-ce-cm2-product-sheet-zh.pdf#page=2",
        "reviewed": "2026-09-08"
      }
    },
    {
      "id": "cycle",
      "@type": "PropertyValue",
      "propertyID": "VT-CE-CM2:cycle",
      "name": "Quick cycle",
      "value": 15,
      "unitText": "s",
      "unitCode": "SEC",
      "description": "≈15 s · Reference value · Designer and product information; handling excluded.",
      "url": "https://cakemoldwasher.com/blog/chiffon-cake-ring-stuck-residue-cleaning/#documented-numbers-cycle",
      "classification": "reference",
      "approximate": true,
      "source": {
        "url": "https://cakemoldwasher.com/media/vtai-ce-cm2-product-sheet-zh.pdf#page=2",
        "reviewed": "2026-09-08"
      }
    },
    {
      "id": "rightDiameter",
      "@type": "PropertyValue",
      "propertyID": "VT-CE-CM2:rightDiameter",
      "name": "Mold diameter / right station",
      "minValue": 6,
      "maxValue": 10,
      "unitText": "in",
      "unitCode": "INH",
      "description": "Documented specification · Confirm material, coating, height and profile with our team. Sample testing is recommended for delicate coatings and unusual shapes.",
      "url": "https://cakemoldwasher.com/blog/chiffon-cake-ring-stuck-residue-cleaning/#mold-numbers-rightDiameter",
      "classification": "documented",
      "approximate": false,
      "source": {
        "url": "https://cakemoldwasher.com/media/vtai-ce-cm2-product-sheet-zh.pdf#page=2",
        "reviewed": "2026-09-08"
      }
    },
    {
      "id": "leftDiameter",
      "@type": "PropertyValue",
      "propertyID": "VT-CE-CM2:leftDiameter",
      "name": "Mold diameter / left station",
      "minValue": 8,
      "maxValue": 14,
      "unitText": "in",
      "unitCode": "INH",
      "description": "Documented specification · Confirm material, coating, height and profile with our team. Sample testing is recommended for delicate coatings and unusual shapes.",
      "url": "https://cakemoldwasher.com/blog/chiffon-cake-ring-stuck-residue-cleaning/#mold-numbers-leftDiameter",
      "classification": "documented",
      "approximate": false,
      "source": {
        "url": "https://cakemoldwasher.com/media/vtai-ce-cm2-product-sheet-zh.pdf#page=2",
        "reviewed": "2026-09-08"
      }
    },
    {
      "id": "model",
      "@type": "PropertyValue",
      "propertyID": "VT-CE-CM2:model",
      "name": "Model",
      "value": "VT-CE-CM2",
      "description": "Documented specification",
      "url": "https://cakemoldwasher.com/specifications/#specification-numbers-model",
      "classification": "documented",
      "approximate": false,
      "source": {
        "url": "https://cakemoldwasher.com/media/vtai-ce-cm2-product-sheet-zh.pdf#page=2",
        "reviewed": "2026-09-08"
      }
    },
    {
      "id": "length",
      "@type": "PropertyValue",
      "propertyID": "VT-CE-CM2:length",
      "name": "Length",
      "value": 1200,
      "unitText": "mm",
      "unitCode": "MMT",
      "description": "Documented specification",
      "url": "https://cakemoldwasher.com/blog/cake-mold-washer-installation-checklist/#documented-numbers-length",
      "classification": "documented",
      "approximate": false,
      "source": {
        "url": "https://cakemoldwasher.com/media/vtai-ce-cm2-product-sheet-zh.pdf#page=2",
        "reviewed": "2026-09-08"
      }
    },
    {
      "id": "width",
      "@type": "PropertyValue",
      "propertyID": "VT-CE-CM2:width",
      "name": "Width",
      "value": 740,
      "unitText": "mm",
      "unitCode": "MMT",
      "description": "Documented specification",
      "url": "https://cakemoldwasher.com/blog/cake-mold-washer-installation-checklist/#documented-numbers-width",
      "classification": "documented",
      "approximate": false,
      "source": {
        "url": "https://cakemoldwasher.com/media/vtai-ce-cm2-product-sheet-zh.pdf#page=2",
        "reviewed": "2026-09-08"
      }
    },
    {
      "id": "height",
      "@type": "PropertyValue",
      "propertyID": "VT-CE-CM2:height",
      "name": "Height",
      "value": 1215,
      "unitText": "mm",
      "unitCode": "MMT",
      "description": "Documented specification",
      "url": "https://cakemoldwasher.com/blog/cake-mold-washer-installation-checklist/#documented-numbers-height",
      "classification": "documented",
      "approximate": false,
      "source": {
        "url": "https://cakemoldwasher.com/media/vtai-ce-cm2-product-sheet-zh.pdf#page=2",
        "reviewed": "2026-09-08"
      }
    },
    {
      "id": "batch",
      "@type": "PropertyValue",
      "propertyID": "VT-CE-CM2:batch",
      "name": "Molds per cycle",
      "value": 2,
      "unitText": "molds/cycle",
      "description": "Documented specification · Designer and product information; handling excluded.",
      "url": "https://cakemoldwasher.com/blog/chiffon-cake-ring-stuck-residue-cleaning/#documented-numbers-batch",
      "classification": "documented",
      "approximate": false,
      "source": {
        "url": "https://cakemoldwasher.com/media/vtai-ce-cm2-product-sheet-zh.pdf#page=2",
        "reviewed": "2026-09-08"
      }
    },
    {
      "id": "motorPower",
      "@type": "PropertyValue",
      "propertyID": "VT-CE-CM2:motorPower",
      "name": "Motors",
      "value": 0.2,
      "unitText": "kW/motor",
      "description": "Documented specification · Electrical power rating, not measured energy consumption.",
      "url": "https://cakemoldwasher.com/blog/cake-mold-washer-installation-checklist/#documented-numbers-motorPower",
      "classification": "documented",
      "approximate": false,
      "source": {
        "url": "https://cakemoldwasher.com/media/vtai-ce-cm2-product-sheet-zh.pdf#page=2",
        "reviewed": "2026-09-08"
      }
    },
    {
      "id": "motors",
      "@type": "PropertyValue",
      "propertyID": "VT-CE-CM2:motors",
      "name": "Motor count",
      "value": 2,
      "unitText": "motors",
      "description": "Documented specification",
      "url": "https://cakemoldwasher.com/blog/cake-mold-washer-installation-checklist/#documented-numbers-motors",
      "classification": "documented",
      "approximate": false,
      "source": {
        "url": "https://cakemoldwasher.com/media/vtai-ce-cm2-product-sheet-zh.pdf#page=2",
        "reviewed": "2026-09-08"
      }
    },
    {
      "id": "voltage",
      "@type": "PropertyValue",
      "propertyID": "VT-CE-CM2:voltage",
      "name": "Voltage",
      "value": 380,
      "unitText": "V",
      "unitCode": "VLT",
      "description": "Documented specification · Quick cycle: approximately 15 seconds for two molds, excluding handling. Confirm 50/60 Hz configuration before ordering. The supplied manual references compressed air; our team will confirm the requirement for the delivered machine.",
      "url": "https://cakemoldwasher.com/blog/cake-mold-washer-installation-checklist/#documented-numbers-voltage",
      "classification": "documented",
      "approximate": false,
      "source": {
        "url": "https://cakemoldwasher.com/media/vtai-ce-cm2-product-sheet-zh.pdf#page=2",
        "reviewed": "2026-09-08"
      }
    },
    {
      "id": "frequency",
      "@type": "PropertyValue",
      "propertyID": "VT-CE-CM2:frequency",
      "name": "Frequency options",
      "value": [
        50,
        60
      ],
      "unitText": "Hz",
      "unitCode": "HTZ",
      "description": "Configuration option · 50 or 60 Hz configuration must be confirmed before ordering; not a continuous adjustment range.",
      "url": "https://cakemoldwasher.com/blog/cake-mold-washer-installation-checklist/#documented-numbers-frequency",
      "classification": "configuration",
      "approximate": false,
      "source": {
        "url": "https://cakemoldwasher.com/media/vtai-ce-cm2-product-sheet-zh.pdf#page=2",
        "reviewed": "2026-09-08"
      }
    },
    {
      "id": "phases",
      "@type": "PropertyValue",
      "propertyID": "VT-CE-CM2:phases",
      "name": "Power phases",
      "value": 3,
      "unitText": "phases",
      "description": "Documented specification · Quick cycle: approximately 15 seconds for two molds, excluding handling. Confirm 50/60 Hz configuration before ordering. The supplied manual references compressed air; our team will confirm the requirement for the delivered machine.",
      "url": "https://cakemoldwasher.com/blog/cake-mold-washer-installation-checklist/#documented-numbers-phases",
      "classification": "documented",
      "approximate": false,
      "source": {
        "url": "https://cakemoldwasher.com/media/vtai-ce-cm2-product-sheet-zh.pdf#page=2",
        "reviewed": "2026-09-08"
      }
    },
    {
      "id": "inlet",
      "@type": "PropertyValue",
      "propertyID": "VT-CE-CM2:inlet",
      "name": "Water inlet size",
      "value": 0.75,
      "unitText": "nominal inches",
      "description": "Documented specification · Nominal connection size; do not interpret it as a measured bore diameter.",
      "url": "https://cakemoldwasher.com/blog/cake-mold-washer-installation-checklist/#documented-numbers-inlet",
      "classification": "documented",
      "approximate": false,
      "source": {
        "url": "https://cakemoldwasher.com/media/vtai-ce-cm2-product-sheet-zh.pdf#page=2",
        "reviewed": "2026-09-08"
      }
    },
    {
      "id": "drain",
      "@type": "PropertyValue",
      "propertyID": "VT-CE-CM2:drain",
      "name": "Drain diameter",
      "value": 38,
      "unitText": "mm",
      "unitCode": "MMT",
      "description": "Documented specification",
      "url": "https://cakemoldwasher.com/blog/cake-mold-washer-installation-checklist/#documented-numbers-drain",
      "classification": "documented",
      "approximate": false,
      "source": {
        "url": "https://cakemoldwasher.com/media/vtai-ce-cm2-product-sheet-zh.pdf#page=2",
        "reviewed": "2026-09-08"
      }
    },
    {
      "id": "material",
      "@type": "PropertyValue",
      "propertyID": "VT-CE-CM2:material",
      "name": "Construction",
      "value": "SUS304",
      "description": "Documented specification",
      "url": "https://cakemoldwasher.com/specifications/#specification-numbers-material",
      "classification": "documented",
      "approximate": false,
      "source": {
        "url": "https://cakemoldwasher.com/media/vtai-ce-cm2-product-sheet-zh.pdf#page=2",
        "reviewed": "2026-09-08"
      }
    },
    {
      "id": "operators",
      "@type": "PropertyValue",
      "propertyID": "VT-CE-CM2:operators",
      "name": "Operators in this arrangement",
      "value": 1,
      "unitText": "operators",
      "description": "Conditional arrangement · Conditional designer statement; verify on site.",
      "url": "https://cakemoldwasher.com/blog/chiffon-cake-ring-stuck-residue-cleaning/#staffing-numbers-operators",
      "classification": "conditional",
      "approximate": false,
      "source": {
        "url": "https://cakemoldwasher.com/blog/chiffon-cake-ring-stuck-residue-cleaning/#article-sources",
        "reviewed": "2026-09-09"
      }
    },
    {
      "id": "attended",
      "@type": "PropertyValue",
      "propertyID": "VT-CE-CM2:attended",
      "name": "Machines attended per operator",
      "minValue": 3,
      "maxValue": 5,
      "unitText": "machines/operator",
      "description": "Conditional arrangement · Conditional designer statement; verify on site.",
      "url": "https://cakemoldwasher.com/blog/chiffon-cake-ring-stuck-residue-cleaning/#staffing-numbers-attended",
      "classification": "conditional",
      "approximate": false,
      "source": {
        "url": "https://cakemoldwasher.com/blog/chiffon-cake-ring-stuck-residue-cleaning/#article-sources",
        "reviewed": "2026-09-09"
      }
    },
    {
      "id": "footprint",
      "@type": "PropertyValue",
      "propertyID": "VT-CE-CM2:footprint",
      "name": "Cabinet footprint",
      "value": 0.888,
      "unitText": "m²",
      "unitCode": "MTK",
      "description": "Calculated example · 1.200 × 0.740 = 0.888 · Length × width only; operating and service clearance is additional.",
      "url": "https://cakemoldwasher.com/blog/cake-mold-washer-installation-checklist/#documented-numbers-footprint",
      "classification": "calculated",
      "approximate": false,
      "formula": "1.200 × 0.740 = 0.888",
      "source": {
        "url": "https://cakemoldwasher.com/media/vtai-ce-cm2-product-sheet-zh.pdf#page=2",
        "reviewed": "2026-09-08"
      }
    },
    {
      "id": "founded",
      "@type": "PropertyValue",
      "propertyID": "VT-CE-CM2:founded",
      "name": "Shenzhen company founded",
      "value": 2015,
      "unitText": "year",
      "description": "Owner-confirmed information",
      "url": "https://cakemoldwasher.com/about/#company-numbers-founded",
      "classification": "owner",
      "approximate": false,
      "source": {
        "url": "https://cakemoldwasher.com/about/#official-websites",
        "reviewed": "2026-09-08"
      }
    },
    {
      "id": "commissioned",
      "@type": "PropertyValue",
      "propertyID": "VT-CE-CM2:commissioned",
      "name": "Zhaoqing base opened",
      "value": 2021,
      "unitText": "year",
      "description": "Owner-confirmed information",
      "url": "https://cakemoldwasher.com/about/#company-numbers-commissioned",
      "classification": "owner",
      "approximate": false,
      "source": {
        "url": "https://cakemoldwasher.com/about/#official-websites",
        "reviewed": "2026-09-08"
      }
    },
    {
      "id": "factoryArea",
      "@type": "PropertyValue",
      "propertyID": "VT-CE-CM2:factoryArea",
      "name": "First-phase factory area",
      "value": 8000,
      "unitText": "m²",
      "unitCode": "MTK",
      "description": "≈8,000 m² · Owner-confirmed information · The Shenzhen company was established in 2015. The Zhaoqing manufacturing base began operation in 2021; its first-phase factory building covers approximately 8,000 m².",
      "url": "https://cakemoldwasher.com/about/#company-numbers-factoryArea",
      "classification": "owner",
      "approximate": true,
      "source": {
        "url": "https://cakemoldwasher.com/about/#official-websites",
        "reviewed": "2026-09-08"
      }
    },
    {
      "id": "elapsed600",
      "@type": "PropertyValue",
      "propertyID": "VT-CE-CM2:elapsed600",
      "name": "Planning time for 600 molds",
      "minValue": 90,
      "maxValue": 120,
      "unitText": "min",
      "unitCode": "MIN",
      "description": "Calculated example · 600 ÷ 400 × 60 = 90; 600 ÷ 300 × 60 = 120 · Planning arithmetic, not a measured production result.",
      "url": "https://cakemoldwasher.com/blog/cake-mold-washer-buying-guide/#guide-calculations-elapsed600",
      "classification": "calculated",
      "approximate": false,
      "formula": "600 ÷ 400 × 60 = 90; 600 ÷ 300 × 60 = 120",
      "source": {
        "url": "https://cakemoldwasher.com/media/vtai-ce-cm2-product-sheet-zh.pdf#page=2",
        "reviewed": "2026-09-08"
      }
    },
    {
      "id": "required600",
      "@type": "PropertyValue",
      "propertyID": "VT-CE-CM2:required600",
      "name": "600 molds / 3-hour window",
      "value": 200,
      "unitText": "molds/h",
      "description": "Planning example · 600 ÷ 3 = 200 · Planning arithmetic, not a measured production result.",
      "url": "https://cakemoldwasher.com/blog/cake-mold-washer-capacity-planning/#documented-numbers-required600",
      "classification": "example",
      "approximate": false,
      "formula": "600 ÷ 3 = 200",
      "source": {
        "url": "https://cakemoldwasher.com/specifications/#numeric-method",
        "reviewed": "2026-09-09"
      }
    },
    {
      "id": "required900",
      "@type": "PropertyValue",
      "propertyID": "VT-CE-CM2:required900",
      "name": "900 molds / 3-hour window",
      "value": 300,
      "unitText": "molds/h",
      "description": "Planning example · 900 ÷ 3 = 300 · Planning arithmetic, not a measured production result.",
      "url": "https://cakemoldwasher.com/blog/cake-mold-washer-capacity-planning/#documented-numbers-required900",
      "classification": "example",
      "approximate": false,
      "formula": "900 ÷ 3 = 300",
      "source": {
        "url": "https://cakemoldwasher.com/specifications/#numeric-method",
        "reviewed": "2026-09-09"
      }
    },
    {
      "id": "required1200",
      "@type": "PropertyValue",
      "propertyID": "VT-CE-CM2:required1200",
      "name": "1200 molds / 3-hour window",
      "value": 400,
      "unitText": "molds/h",
      "description": "Planning example · 1200 ÷ 3 = 400 · Planning arithmetic, not a measured production result.",
      "url": "https://cakemoldwasher.com/blog/cake-mold-washer-capacity-planning/#documented-numbers-required1200",
      "classification": "example",
      "approximate": false,
      "formula": "1200 ÷ 3 = 400",
      "source": {
        "url": "https://cakemoldwasher.com/specifications/#numeric-method",
        "reviewed": "2026-09-09"
      }
    },
    {
      "id": "hypothetical150",
      "@type": "PropertyValue",
      "propertyID": "VT-CE-CM2:hypothetical150",
      "name": "Hypothetical 150 molds / 40 minutes",
      "value": 225,
      "unitText": "molds/h",
      "description": "Planning example · 150 ÷ 40 × 60 = 225 · Planning arithmetic, not a measured production result.",
      "url": "https://cakemoldwasher.com/blog/cake-mold-washer-capacity-planning/#documented-numbers-hypothetical150",
      "classification": "example",
      "approximate": false,
      "formula": "150 ÷ 40 × 60 = 225",
      "source": {
        "url": "https://cakemoldwasher.com/specifications/#numeric-method",
        "reviewed": "2026-09-09"
      }
    },
    {
      "id": "ceiling",
      "@type": "PropertyValue",
      "propertyID": "VT-CE-CM2:ceiling",
      "name": "No-interruption arithmetic ceiling",
      "value": 480,
      "unitText": "molds/h",
      "description": "Calculated example · 3600 ÷ 15 × 2 = 480 · 3600 ÷ 15 × 2; not measured output.",
      "url": "https://cakemoldwasher.com/blog/chiffon-cake-ring-stuck-residue-cleaning/#batch-calculations-ceiling",
      "classification": "calculated",
      "approximate": false,
      "formula": "3600 ÷ 15 × 2 = 480",
      "source": {
        "url": "https://cakemoldwasher.com/media/vtai-ce-cm2-product-sheet-zh.pdf#page=2",
        "reviewed": "2026-09-08"
      }
    },
    {
      "id": "rightMm",
      "@type": "PropertyValue",
      "propertyID": "VT-CE-CM2:rightMm",
      "name": "Mold diameter / right station",
      "minValue": 152.4,
      "maxValue": 254,
      "unitText": "mm",
      "unitCode": "MMT",
      "description": "Calculated example · 6 × 25.4 = 152.4; 10 × 25.4 = 254 · Confirm material, coating, height and profile with our team. Sample testing is recommended for delicate coatings and unusual shapes.",
      "url": "https://cakemoldwasher.com/blog/non-stick-cake-mold-brush-cleaning/#documented-numbers-rightMm",
      "classification": "calculated",
      "approximate": false,
      "formula": "6 × 25.4 = 152.4; 10 × 25.4 = 254",
      "source": {
        "url": "https://cakemoldwasher.com/media/vtai-ce-cm2-product-sheet-zh.pdf#page=2",
        "reviewed": "2026-09-08"
      }
    },
    {
      "id": "leftMm",
      "@type": "PropertyValue",
      "propertyID": "VT-CE-CM2:leftMm",
      "name": "Mold diameter / left station",
      "minValue": 203.2,
      "maxValue": 355.6,
      "unitText": "mm",
      "unitCode": "MMT",
      "description": "Calculated example · 8 × 25.4 = 203.2; 14 × 25.4 = 355.6 · Confirm material, coating, height and profile with our team. Sample testing is recommended for delicate coatings and unusual shapes.",
      "url": "https://cakemoldwasher.com/blog/non-stick-cake-mold-brush-cleaning/#documented-numbers-leftMm",
      "classification": "calculated",
      "approximate": false,
      "formula": "8 × 25.4 = 203.2; 14 × 25.4 = 355.6",
      "source": {
        "url": "https://cakemoldwasher.com/media/vtai-ce-cm2-product-sheet-zh.pdf#page=2",
        "reviewed": "2026-09-08"
      }
    },
    {
      "id": "overlap",
      "@type": "PropertyValue",
      "propertyID": "VT-CE-CM2:overlap",
      "name": "Station diameter overlap",
      "minValue": 8,
      "maxValue": 10,
      "unitText": "in",
      "unitCode": "INH",
      "description": "Calculated example · [6, 10] ∩ [8, 14] = [8, 10] · Confirm material, coating, height and profile with our team. Sample testing is recommended for delicate coatings and unusual shapes.",
      "url": "https://cakemoldwasher.com/blog/non-stick-cake-mold-brush-cleaning/#documented-numbers-overlap",
      "classification": "calculated",
      "approximate": false,
      "formula": "[6, 10] ∩ [8, 14] = [8, 10]",
      "source": {
        "url": "https://cakemoldwasher.com/media/vtai-ce-cm2-product-sheet-zh.pdf#page=2",
        "reviewed": "2026-09-08"
      }
    },
    {
      "id": "overlapMm",
      "@type": "PropertyValue",
      "propertyID": "VT-CE-CM2:overlapMm",
      "name": "Station diameter overlap",
      "minValue": 203.2,
      "maxValue": 254,
      "unitText": "mm",
      "unitCode": "MMT",
      "description": "Calculated example · 8 × 25.4 = 203.2; 10 × 25.4 = 254 · Confirm material, coating, height and profile with our team. Sample testing is recommended for delicate coatings and unusual shapes.",
      "url": "https://cakemoldwasher.com/blog/non-stick-cake-mold-brush-cleaning/#documented-numbers-overlapMm",
      "classification": "calculated",
      "approximate": false,
      "formula": "8 × 25.4 = 203.2; 10 × 25.4 = 254",
      "source": {
        "url": "https://cakemoldwasher.com/media/vtai-ce-cm2-product-sheet-zh.pdf#page=2",
        "reviewed": "2026-09-08"
      }
    },
    {
      "id": "inchConversion",
      "@type": "PropertyValue",
      "propertyID": "VT-CE-CM2:inchConversion",
      "name": "Millimeters per inch",
      "value": 25.4,
      "unitText": "mm/in",
      "description": "Exact conversion · 1 in = 25.4 mm",
      "url": "https://cakemoldwasher.com/blog/non-stick-cake-mold-brush-cleaning/#documented-numbers-inchConversion",
      "classification": "conversion",
      "approximate": false,
      "formula": "1 in = 25.4 mm",
      "source": {
        "url": "https://www.nist.gov/pml/owm/si-units-length",
        "reviewed": "2026-09-09"
      }
    },
    {
      "id": "quantity120",
      "@type": "PropertyValue",
      "propertyID": "VT-CE-CM2:quantity120",
      "name": "Example batch quantity",
      "value": 120,
      "unitText": "molds",
      "description": "Planning example · Planning arithmetic, not a measured production result.",
      "url": "https://cakemoldwasher.com/blog/chiffon-cake-ring-stuck-residue-cleaning/#batch-calculations-quantity120",
      "classification": "example",
      "approximate": false,
      "source": {
        "url": "https://cakemoldwasher.com/specifications/#numeric-method",
        "reviewed": "2026-09-09"
      }
    },
    {
      "id": "cycles120",
      "@type": "PropertyValue",
      "propertyID": "VT-CE-CM2:cycles120",
      "name": "Cycles for 120 molds",
      "value": 60,
      "unitText": "cycles",
      "description": "Calculated example · 120 ÷ 2 = 60 · Planning arithmetic, not a measured production result.",
      "url": "https://cakemoldwasher.com/blog/chiffon-cake-ring-stuck-residue-cleaning/#batch-calculations-cycles120",
      "classification": "calculated",
      "approximate": false,
      "formula": "120 ÷ 2 = 60",
      "source": {
        "url": "https://cakemoldwasher.com/media/vtai-ce-cm2-product-sheet-zh.pdf#page=2",
        "reviewed": "2026-09-08"
      }
    },
    {
      "id": "active120",
      "@type": "PropertyValue",
      "propertyID": "VT-CE-CM2:active120",
      "name": "Washing-only time for 120 molds",
      "value": 15,
      "unitText": "min",
      "unitCode": "MIN",
      "description": "Calculated example · 120 ÷ 2 × 15 ÷ 60 = 15 · Washing time only; excludes handling, checks and interruptions.",
      "url": "https://cakemoldwasher.com/blog/chiffon-cake-ring-stuck-residue-cleaning/#batch-calculations-active120",
      "classification": "calculated",
      "approximate": false,
      "formula": "120 ÷ 2 × 15 ÷ 60 = 15",
      "source": {
        "url": "https://cakemoldwasher.com/media/vtai-ce-cm2-product-sheet-zh.pdf#page=2",
        "reviewed": "2026-09-08"
      }
    },
    {
      "id": "elapsed120",
      "@type": "PropertyValue",
      "propertyID": "VT-CE-CM2:elapsed120",
      "name": "Planning time for 120 molds",
      "minValue": 18,
      "maxValue": 24,
      "unitText": "min",
      "unitCode": "MIN",
      "description": "Calculated example · 120 ÷ 400 × 60 = 18; 120 ÷ 300 × 60 = 24 · Planning arithmetic, not a measured production result.",
      "url": "https://cakemoldwasher.com/blog/chiffon-cake-ring-stuck-residue-cleaning/#batch-calculations-elapsed120",
      "classification": "calculated",
      "approximate": false,
      "formula": "120 ÷ 400 × 60 = 18; 120 ÷ 300 × 60 = 24",
      "source": {
        "url": "https://cakemoldwasher.com/media/vtai-ce-cm2-product-sheet-zh.pdf#page=2",
        "reviewed": "2026-09-08"
      }
    }
  ]
}